YAG50 marking and treatment of common faults Core Tip: a non-luminous one, the old Q drive ON, OFF, RUN three stalls wrong choice, OFF command was forced off the laser, ON mandatory luminous command, the correct way is to select RUN Run . 2
YAG50 marking and treatment of common faults
Core Tip: a non-luminous one, the old Q drive ON, OFF, RUN three stalls wrong choice, OFF command was forced off the laser, ON mandatory luminous command, the correct way is to select RUN Run . 2, board bad, replace the board. Q on-board signal voltage, under normal circumstances, Q ... a signal, does not light a, the old Q drive ON, OFF, RUN three gear selection error, OFF is forced off the laser command, ON mandatory luminous command, the correct way is to select RUN to run. 2, board bad, replace the board. Q signal voltage on the board, under normal circumstances, the voltage signal is Q: When KAIRUI board is low, i.e., when the marking is 0V, and no marking of the +5 V; JCZ marked playing cards high, that is 5V marking when not marking to 0V. 3, the signal connection board and drive open, replace or re-welded good. 4, the optical path is not fine, re-adjust the optical path. 5, krypton lamp is broken, replace krypton lamps. 6, the computer operating system or computer failure, reinstall the system or replace the computer. 7, the laser power is bad, replace the laser power. 8, Q drive is broken, replace the Q drive. 9, Q switch is bad, replace the Q-switch. Second, a weak light, marking software CW mode is not selected, the light will be very weak, select CW mode. 2, M1 Q drive, M2, M3 dialed the wrong gear, the right way is to select the M1. 3, the focal length is wrong, re-adjust the focus. 4, the water temperature is too high. 5, krypton lamp aging, replacement krypton lamp. 6, all-trans or semi-reflective lens, focusing lens, lens galvanometer, Q switching lens is dirty or scratch. Clean or replace. 7, the cavity, the total reflection mirror, the half mirror and the beam expander is not fine, re-adjusted. 8, Q switch is not fine, normally when marking is light, when not marking Q switch to lock the laser. Laser power supply current can be adjusted appropriately large pieces on the octave before half mirror to see if there is no light leakage. If leaked, the light will be very weak, re-adjust the Q switch. 9, did not play in the galvo laser center, or galvanometer lens scratches. Re-adjust the optical path, or replace the galvanometer. Third, a continuous light, the wrong switch the order could result in continuous light. Correct boot order: After READY lamp total power => PC => Marking Software => Chiller => Q drive => Laser Power => etc. shock power on bright => Press RUN key to start => galvanometer power switch . Off the opposite order. 2, the old Q drive ON, OFF, RUN switch gear fault, ON command to force the luminous, OFF is forced off the laser command, the correct way is to select RUN to run. 3, the board bad, replace the board. KAIRUI board should also note that the above board jumpers: YAG50 jumper should jump T side. (Note that some board when replacing KAIRUI this issue) 4, Q switch is not fine, normally when marking is light, when not marking Q switch to lock the laser. 6, in the case KAIRUI software also may be due to marking software problem, reinstall. 7, computer or operating system problems. Replace or reinstall the system. 8, Q drive is broken, replace the Q drive. 9, Q switch is bad, replace the Q-switched (fewer such cases, in general Q-switch is broken, Q drive will alarm) Fourth, do not move a galvanometer, the parameter X software on KAIRUI, Y scaling options are zero galvanometer will not move, re-adjust the parameters. 2, board bad, replace the board. On board X, Y galvanometer voltage signal, the normal situation is: when marking is varied between 0-5V, when not marking to 0V. 3, galvanometer signal lines open, replace it. 4, Qinlong galvanometer, by jumpers on the drive signal lights must be pulled out next, otherwise it will not move galvanometer. 5, galvanometer failure, replace the galvanometer. 6, the computer operating system or computer failure, reinstall the system or replace the computer. Fifth, jitter and whistle a galvanometer, the ground is not connected, re-connect the ground wire. 2, board bad, replace the board. 3, turn off the laser power, Q drive, gently touching the lens is vibrating mirror galvanometer whether jitter or listening to the howling, if troubleshooting, and then one by one turn on the laser power and the Q drive to determine the laser power or cause Q drive . 4, if it is caused because the laser power galvanometer jitter or whistle can be laser power supply high voltage and other signal lines as much as possible to separate these generally can troubleshooting. If the problem persists, replace the laser power. 5, if it is because Q galvanometer drive causing jitter or whistle, you should check the connection Q and Q-switch drive short circuit between the signal line short circuit will cause this failure. If the problem persists, replace the Q drive. 6, galvanometer bad, replace the galvanometer. 7, the computer operating system or computer failure, reinstall the system or replace the computer. Six KAIRUI marking software will automatically shut down after opening (YMDF, consistent RF series marking machine processing method) 1, dongle is not installed, reinstall it. 2, the dongle driver is not installed, re-install the driver. Seven, marking ineffective (YMDF, RF series marking machine html模版YAG50打标机常见故障及处理方法
核心提示:一、不发光1、老式Q驱动器上ON、OFF、RUN三个档位选择错误,OFF为强制关断激光命令,ON为强制发光命令,正确的方式是选择RUN运行。2、板卡坏,更换板卡。板卡上Q信号电压,正常情况下,Q信号的...一、不发光1、老式Q驱动器上ON、OFF、RUN三个档位选择错误,OFF为强制关断激光命令,ON为强制发光命令,正确的方式是选择RUN运行。2、板卡坏,更换板卡。板卡上Q信号电压,正常情况下,Q信号的电压是:凯锐板卡时为低电平,即打标时为0V,不打标时为+5V;金橙子板卡打标时为高电平,即打标时为5V,不打标时为0V。3、板卡与驱动器上的信号连线开路,更换或者重新焊接好。4、光路没有调好,重新调整光路。5、氪灯坏,更换氪灯。6、电脑操作系统或电脑故障,重装系统或更换电脑。7、激光电源坏,更换激光电源。8、Q驱动器坏,更换Q驱动器。9、Q开关坏,更换Q开关。二、光弱1、打标软件CW方式没有选中,光会很弱,选取CW方式。2、Q驱动器上的M1、M2、M3档位拨错,正确的方式是选择M1。3、焦距不对,重新调整焦距。4、水温过高。5、氪灯老化,更换氪灯。6、全反或半反射镜片、聚焦镜片、振镜镜片、Q开关的镜片脏或擦花。擦干净或更换。7、腔体,全反射镜,半反射镜和扩束镜没有调好,重新调整。8、Q开关没有调好,正常情况为打标时发光,不打标时Q开关要锁住激光。可将激光电源的电流恰当调大,将倍频片放在半反射镜之前看有没有漏光。如果漏光,光会很弱,重新调整Q开关。9、激光没有打在振镜中心,或者是振镜的镜片刮花。重调光路,或更换振镜。三、连续发光1、错误的开关机顺序均可能会导致连续出光。正确的开机顺序为:总电源=>电脑=>打标软件=>冷水机=>Q驱动器=>激光电源=>等激电源上的READY灯亮后=>按RUN键启动=>振镜电源开关。关机顺序与之相反。2、老式Q驱动器上ON、OFF、RUN档位开关拨错,ON为强制发光命令,OFF为强制关断激光命令,正确的方式是选择RUN运行。3、板卡坏,更换板卡。凯锐板卡还应注意板卡上面的跳线帽:YAG50跳线帽应跳T端。(更换凯锐板卡时一定注意此问题)4、Q开关没有调好,正常情况为打标时发光,不打标时Q开关要锁住激光。6、如是凯锐软件还可能是因为打标软件问题,重新安装。7、电脑或操作系统问题。更换或重装系统。8、Q驱动器坏,更换Q驱动器。9、Q开关坏,更换Q开关(这种情况较少,一般来说Q开关坏了,Q驱动器会报警)四、振镜不动1、凯锐软件上的参数X、Y比例调整选项是为零,振镜会不动,重新调整参数。2、板卡坏,更换板卡。板卡上X、Y振镜信号的电压,正常情况是:打标时为0-5V之间变化,不打标时为0V。3、振镜信号线开路,更换。4、秦龙的振镜,驱动器上靠信号指示灯旁的跳线帽一定要拨掉,否则振镜也不会动。5、振镜故障,更换振镜。6、电脑操作系统或电脑故障,重装系统或更换电脑。五、振镜抖动和啸叫1、地线没有接好,重新接好地线。2、板卡坏,更换板卡。3、关掉激光电源,Q驱动器,用手轻轻接触振镜的镜片是否抖动或听振镜是否啸叫,如果故障排除,再逐一打开激光电源和Q驱动器,以判断是激光电源还是Q驱动器引起。4、如果是因为激光电源引起振镜抖动或啸叫,可将激光电源的高压线与其它的信号线尽可能的分开些,一般来说可将故障排除。如果故障仍然存在,更换激光电源。5、如果是因为Q驱动器引起振镜抖动或啸叫,则应该检查Q驱动器与Q开关之间的连线是否短路,该信号线短路会导致此故障。如故障仍然存在,可更换Q驱动器。6、振镜坏,更换振镜。7、电脑操作系统或电脑故障,重装系统或更换电脑。六、凯锐打标软件打开之后会自动关闭(YMDF、RF系列打标机处理方法一致,)1、加密狗没有装好,重新安装。2、加密狗的驱动没有装好,重新安装驱动。七、打标效果不好(YMDF、RF系列打标机(责任编辑:admin)
相关内容:
Chinese laser industry resea